Frozen holdout contract: default switch to velocity_consistency_v6 (v1)

This contract is frozen in a commit before any candidate replay of the holdout data. It decides whether the online PVA production default should become velocity_consistency_v6. The development record for that candidate is online_pva_candidate_v7.md and its results.

That record was built only on the six PPC-Dataset runs. Every one of those runs was used to diagnose and design v1-v6. This contract evaluates the candidate, unchanged, on data that played no part in its development.

Go here does not switch the default by itself. Go means a separate, reviewed PR proposes the switch to the maintainer. No-Go keeps the default and is recorded like every earlier No-Go.

Holdout data

UrbanNav Tokyo, 2018-12-19 (IPNL-POLYU/UrbanNavDataset, Tokyo_Data.zip on Dropbox), runs Odaiba (1,241 s) and Shinjuku (2,095 s).

  • Instruments:
  • Rover receivers: Trimble NetR9 at 10 Hz and u-blox at 5 Hz.
  • Base: Trimble NetR9, 1 Hz, site CREF0001.
  • Navigation: multi-GNSS broadcast merge (base.nav).
  • IMU: 50 Hz.
  • Truth: Applanix POS LV, 10 Hz, with position, ENU velocity, roll, pitch and heading.
  • Independence from PPC 2024:
  • It is a different year, vehicle, rover receiver and IMU, and a different drive.
  • It shares the base site with PPC Tokyo, and the Odaiba area is near PPC Tokyo 3. The data does not overlap.
  • What was looked at before this freeze, all during a format survey:
  • Headers.
  • Rates and gaps.
  • Constellations and signals.
  • Baseline lengths from truth positions.
  • The IMU axes, from the specific force at rest and the correlation of gyro z with truth heading rate.
  • An IMU-versus-truth time cross-correlation.
  • What was not run before this freeze: no estimator of this repository (none or any candidate) was run on this data, and no accuracy metric was computed.
  • The data is not redistributed. The repository records the SHA256 of each raw and converted file, not the files.

Conversion to the PPC run layout (fixed here, no tuning)

scripts/convert_urbannav_to_ppc_layout.py writes, per run, a directory <root>/urbannav/<run>_trimble/ holding the PPC file set. Only the Trimble rover is used; the section below explains why u-blox is excluded.

  1. rover.obs: rover_trimble.obs, keeping only epochs that satisfy both conditions below. Header and observation records are otherwise byte-preserved.
  2. The GPS time of week is a multiple of 0.2 s.
  3. The epoch lies within the time span of the converted reference.csv (first to last row, inclusive). The scorer requires every emitted epoch to have a truth row.
  4. base.obs: base_trimble.obs, unchanged.
  5. base.nav: base.nav, unchanged.
  6. imu.csv: PPC header and units. The steps, in order:
  7. Axes. The UrbanNav IMU is FRD; it is mapped to FLU with x -> x, y -> -y, z -> -z for both the accelerometer and the gyro. The evidence is the specific force at rest, z = -9.78 m/s^2, and a +0.9997 correlation of gyro z with the clockwise-from-north truth heading rate.
  8. Units. Gyro rad/s -> deg/s.
  9. Wheel speed is dropped.
  10. Resampling. UrbanNav IMU timestamps are not on a fixed grid. The replay requires an IMU sample at each rover epoch, within 1e-6 s. So the samples are resampled by linear interpolation onto the grid t = k x 0.02 s (50 Hz) of GPS time of week.
    • A grid point is written when it lies after one raw sample and at or before the next, and those two samples are at most 0.1 s apart. A grid point that coincides with a raw sample therefore takes that sample's value.
    • No extrapolation is done, and no time offset is applied.
  11. reference.csv: PPC header names. Velocity X/Y/Z are renamed to East/North/Up Velocity (m/s); the survey showed they are ENU. Only rows whose GPS time of week is a multiple of 0.2 s are kept. Everything else is copied unchanged, including six trailing acceleration and angular-rate columns that PPC does not have and the scorer ignores.

Replay configuration (fixed here)

gnss_pva_replay accepts a third layout, urbannav/<run>, in addition to PPC tokyo|nagoya/<run>.

  • Lever arm. For urbannav the antenna lever arm is (0, 0, 0) m in FLU.
  • UrbanNav documents no antenna-IMU lever arm for Tokyo. The maintainer chose zero as a declared assumption instead of a value estimated from data.
  • Control and candidate use the same zero lever arm.
  • Everything else is the configuration the replay already uses: the base position from the base RINEX header, RTK settings, initialization and time handling.
  • PPC is unaffected. The tokyo and nagoya branches are unchanged, and PPC outputs stay bit-identical (gate 7).

Population and comparison

  • Population: 2 runs (Odaiba, Shinjuku) with the Trimble rover x 3 scenarios.
  • Normal.
  • GNSS outage, 60-70 s.
  • IMU gap, 60-64 s.
  • That is 6 control replays (--candidate none, the current production default) and 6 candidate replays (--candidate velocity_consistency_v6). Both are built from the same binary and interleaved on the same quiet host, at most 3 at once.
  • The existing comparator scripts/analysis/compare_online_pva.py gains a --runs option and is invoked once with --runs Odaiba_trimble Shinjuku_trimble. Its default run list and every gate are unchanged.
  • The base is 1 Hz, so only every fifth 5 Hz rover epoch has an exact base epoch. The other epochs use the replay's existing SPP fallback, in control and candidate alike.

Acceptance (the frozen gates, applied per run/scenario)

  1. RTK and fused position, RTK and fused velocity, and full-rotation RMSE and P95 are each <= 1.01 x control. This holds on both the all-output and the common-valid cohorts.
  2. Coverage loses at most 0.1 percentage point. Coverage here is the RTK, fused, velocity, attitude and heading availability.
  3. The first fresh attitude and the first heading latch come no later. The scenario GNSS-update, fresh-attitude and heading recovery also come no later. A null value is censored, never zero.
  4. Processor P95 <= 2 x control.
  5. At least one normal-run full-rotation RMSE/P95 improvement.
  6. Missing metrics, scenarios, truth mismatches or input-hash mismatches fail.
  7. Candidate none built from the candidate tree is bit-identical to candidate none from the develop commit this branch starts from. This covers every deterministic CSV field on the 18 PPC runs.

Go only if every gate passes on all 6 run/scenarios. Otherwise record No-Go with the failed gates, and keep the default. Do not change the candidate, the conversion or the configuration after seeing any holdout result.

Pipeline smoke allowed before the candidate run

  • Allowed run: one bounded control-only replay, --candidate none --max-epochs 300, on each converted directory.
  • What it checks: that the conversion and the layout run, meaning state passed and a nonzero fused availability.
  • What it does not look at: no error metric is read. This is recorded in the results.
  • If the smoke fails: if it fails for a format reason, the converter may be fixed to meet this contract's specification. The specification itself does not change. The fix and its reason are recorded.

Change before the freeze: u-blox excluded

The first draft (d0fc112b) also had a u-blox rover set, copied unchanged at 5 Hz. The allowed control-only smoke on four directories showed a format problem: the u-blox epochs are mostly 1-3 ms off the 0.2 s grid.

  • Odaiba: 6,069 of 6,206 epochs are off the grid.
  • Shinjuku: 7,768 of 10,476 epochs are off the grid.

The scorer matches truth by exact timestamp, and the replay needs base and IMU epochs within 1e-6 s. So these sets cannot be scored. On Shinjuku the fused filter never initialized.

Re-timing the observations would alter the measurement data, so the u-blox rover is excluded instead. Only state and availability were read in that smoke; no error metric was read, and no candidate was run.

The same smoke, on the Trimble sets, showed a match fraction of 0.9967. The first rover epoch (Odaiba 273375.0 s) precedes the first 0.2 s truth row (273375.2 s), and the comparator requires every epoch to match. Rover epochs are therefore limited to the truth span, as rule 1 states.

The same review changed the IMU grid rule. A grid point that coincides with a raw sample is now kept, where the draft skipped it as "strictly inside no pair". The draft rule skipped 4 and 6 such points.

Final pre-freeze smoke

The final control-only smoke used the frozen converter: 300 epochs, normal scenario. Only state, availability and match fraction were read; no error metric was read.

Directory State Fused availability RTK availability Match fraction
Odaiba_trimble passed 0.967 1.0 1.0
Shinjuku_trimble passed 0.967 1.0 1.0

An offline check of the full converted runs, which did not involve the estimator, confirmed that every kept rover epoch has an exact truth row:

  • Odaiba: 6,199 epochs, 0 without a truth row.
  • Shinjuku: 10,395 epochs, 0 without a truth row.

Reported in addition (not gates)

  • Absolute errors, with the warning that the zero lever arm and the unknown truth reference point bias them by up to about 1 m.
  • The IMU-versus-truth time offset of about 0.15 s seen in the survey. It is not corrected, and it affects both control and candidate.
  • Per-run v6 behaviour: direction-test flips, rover-gap RTK-only resets and gyro-bias seeds.