Skip to content

Camera intrinsics without a target

calibrex intrinsics rotate estimates a camera's intrinsics from a recording of the camera turned in place: no checkerboard. When a camera only rotates, where a scene point appears in one frame fixes where it appears in every other frame through the intrinsics and the rotation alone, so panning, tilting and rolling the camera over a textured, static scene determines the focal lengths, the principal point and the lens distortion. The result is a Kalibr camchain entry (pinhole / radtan: k1 k2 p1 p2, or equidistant: k1..k4 with --distortion equidistant for fisheye lenses), like calibrex intrinsics guide writes.

Run it

From a ROS bag, a video, or a live camera (recorded for --seconds, default 20):

calibrex intrinsics rotate --bag my_bag --topic /camera/image_raw
calibrex intrinsics rotate --video turning.mp4
calibrex intrinsics rotate --camera 0 --resolution 1280x720 --seconds 20

For a ROS 1 .bag with raw sensor_msgs/Image messages or a ROS 2 bag, use --start-seconds 12 --seconds 10 to use the interval from 12 to 22 seconds after the topic's first image stamp.

With a live camera a window guides the turning (below) and the calibration starts as soon as the turns are enough; --no-window records for --seconds without it.

For a fisheye lens add --distortion equidistant. On a simulated 110 deg fisheye (480 x 360, f = 235 px, Kannala-Brandt k1..k4) turned for 8 s, the focal lengths came within 0.2 %, the principal point within 0.5 px, and the fitted model put pixels in the image corners within 0.5 deg of their true directions. The guide window then reads the turns through an ideal fisheye of 0.45 times the image width.

It needs OpenCV (pip install 'calibrex[opencv]'; the live window needs opencv-python, not the headless build). --output (default intrinsics_camchain.yaml) and --camera-name (default cam0) name the camchain; --json prints the result as JSON.

Stereo

A stereo rig turned in place gives both cameras' intrinsics and their relative rotation. Pass the right camera as a second topic, a second video, or a side-by-side stream:

calibrex intrinsics rotate --bag my_bag --topic /left/image_raw --right-topic /right/image_raw
calibrex intrinsics rotate --video left.mp4 --right-video right.mp4
calibrex intrinsics rotate --video stereo.mp4 --side-by-side --baseline-m 0.12
calibrex intrinsics rotate --camera 0 --side-by-side --seconds 20

The camchain gets cam0 (left) and cam1 (right). Both cameras turn together, so between any two moments the right camera's rotation is the left camera's seen in the right camera's axes; aligning the two rotation sequences (keyframes matched by time, left orientations interpolated) gives the relative rotation. Bag topics are paired by their header stamps, so the cameras must share a clock. Two separate live cameras cannot be recorded in step here: record them to a bag or to videos.

The baseline is harder. Its length is not observable from rotation, so T_cn_cnm1 is written only with --baseline-m. Its direction comes from features matched between simultaneous left and right images, and a rotation error tilts it by about the rotation error over the parallax angle (in a narrow field a rotation about the camera's y axis and a translation along x look alike). It is reported only when the matches' median parallax is at least 2 px and ten times the rotation's error in pixels; otherwise the command says so and leaves T_cn_cnm1 out. On a simulated 10 cm rig turned in a room 16 m across, the intrinsics came within 0.4 % (focal) and 4 px (principal point), the relative rotation within 0.7 deg (0.2 deg in a room 40 m across), and the parallax (under 1 px) was too small for a direction. With the true rotation and objects 2-3.5 m away the direction came within 3 deg, but a rotation 0.5 deg off is already too coarse for it. Use a checkerboard when the full stereo extrinsics matter.

Turning a rig about its middle also offsets each lens by half the baseline from the rotation centre, which lengthens the focal lengths by about 0.8 (b/2)/D: face a distant scene.

Rolling shutter

Most webcams and phone cameras read the frame out row by row, so a camera turned briskly sees each row a little later, turned a little further. Ignoring that bends the fit: --rolling-shutter also fits the readout time (first row to last), turning each row's view on by the keyframe's angular velocity times the row's delay. The camchain then carries readout_s, which Calibrex's camera pairs (camera-imu, camera-focal) read.

On a simulated camera (320 x 240, f = 280 px) read out in 30 ms and turned up to about 50 deg/s, the fit gave a readout of 31.1 ± 0.2 ms, the focal length within 0.05 % and the principal point within 0.7 px; without --rolling-shutter the focal length came out 1.5 % long and the principal point 16 px off. The fit runs the global-shutter fit first, then refines with the readout (about twice the time). On RobotNativeEngine's simulated camera read out in 30 ms (in 24 bands) and turned more slowly, it estimated 25.9 ± 0.5 ms and moved the principal point from 0.9 px to 0.5 px off; there the readout cost little.

How to record

  • Turn the camera about its lens. This is what matters most. A camera on a tripod or a pan-tilt head is ideal; by hand, hold it close to the lens and rotate it, not your arm.
  • Face a static, textured scene, as far away as you can. Outdoors, a street or a building façade tens of metres away; indoors, a cluttered room. Nothing should move.
  • Pan, tilt and roll, each by 20 deg or more, for 10-20 s. Turning about one axis only leaves the focal length undetermined; the command warns when fewer than two axes turned 20 deg.
  • Turn smoothly: features are tracked frame to frame and dropped when tracking them back misses by more than 0.3 px.

The guide window

--camera shows the live image with what to do next, and --video --guide shows the same over a recording (--no-window --record annotated.avi writes it to a video instead):

  • Point the camera at a static scene with more texture: fewer than 60 features are tracked.
  • Slower: the features moved more than 6 % of the image width in one frame, or half of them were lost.
  • Pan, then Tilt, then Roll, with how far the camera has turned about that axis and the 25 deg it should reach. A bar per axis fills as you turn and turns green.
  • Done: all three axes turned 25 deg over at least 20 keyframes. The live camera then stops and calibrates; s calibrates earlier, q quits.

The guide turns the image motion between keyframes into a rotation with a guessed focal length (0.8 times the image width, about 64 deg across), so its angles are approximate: a guess 20 % off reads pan and tilt 20 % off, while roll is exact. The 25 deg target leaves room above the 20 deg the calibration needs. On a simulated camera (280 px focal length, k1 = -0.12) a person sweeping each axis as told reached done in about 80 frames (8 s at 10 fps), pan and tilt read within 10 % of the truth, roll within 1.5 deg, and the calibration of those frames gave the focal length within 0.3 %.

The guide cannot tell whether you turn about the lens: the lens distortion bends the image motion as much as a few centimetres of translation, so it only reminds you.

What it reports

The camchain, the intrinsics with their stds, the transfer error (how far a tracked feature lands from where the fitted rotation and intrinsics put it, in pixels: its RMS and its median), the number of keyframes, how far the camera turned about its x (tilt), y (pan) and z (roll) axes, and warnings.

The command warns when the median transfer error is above 1 px: the scene moved or the features are tracked poorly. It judges the median, not the RMS, because the RMS follows the tail of poorly tracked features: on RobotNativeEngine's simulated room, rendered one ray per pixel so its edges alias, a camera that only turned gave a median of 0.48 px and an RMS of 1.13 px. A translation of the camera does not raise either (see below).

The stds come from the fit's Jacobian, scaled for each tracked point entering several keyframe pairs. They do not include the bias below.

The limit: translation

A hand-held camera also translates as it turns, and the intrinsics take up the parallax of that translation without raising the residual, so the data alone cannot show it. On a simulated camera (480 x 360, barrel distortion k1 = -0.12, a textured room 8 m across):

Lens offset from the rotation centre Scene distance Focal-length error
0 (turned about the lens) 4 m -0.08 % (principal point within 0.2 px, k1 -0.1202)
5 cm 4 m +0.9 %
5 cm 2 m +1.9 %
15 cm 4 m +2.8 %
15 cm 10 m +1.1 %

The focal length comes out too long by about 0.8 times the offset over the distance. For 0.5 % (enough to start a camera-LiDAR or camera-IMU calibration), turn the camera about its lens, or keep the offset under about 1/150 of the scene distance. When the focal length must be known to 0.1 %, use a checkerboard (calibrex intrinsics guide).

Real-data results (TUM-VI)

The TUM-VI dataset provides these 512 × 512 global-shutter fisheye recordings. The audit estimates each camera independently with --distortion equidistant. It uses OptiTrack rig poses to choose a 10 s window with rotation about at least two axes and the smallest measured rig displacement. Only the image stream enters the fit. The published Kalibr camchain supplies the reference values for scoring.

The pre-registration was committed as 3112f7df after development on room1. It requires both absolute focal errors to be at most 5% and both absolute principal-point errors to be at most 5 px. At least five of the ten evaluation cases must pass. Inconclusive estimates contribute zero passes. The distortion coefficients are reported as signed differences. The earlier camera-focal and camera-IMU checks had used the evaluation recordings.

In the table, focal errors are percentages of the reference focal lengths. Principal-point and coefficient errors are estimate minus reference. The development verdicts apply the evaluation gates retrospectively.

Split Sequence Camera Δfx (%) Δfy (%) Δcx (px) Δcy (px) Δk1 Δk2 Δk3 Δk4 Verdict
Development room1 cam0 +23.88 +22.12 +0.26 -2.74 -0.0408 -0.0039 +0.0018 -0.0027 fail
Development room1 cam1 +22.58 +21.24 -0.44 -1.89 -0.0410 -0.0005 +0.0008 -0.0026 fail
Evaluation room2 cam0 +28.66 +28.48 +3.01 +0.84 -0.0518 -0.0026 +0.0062 -0.0032 fail
Evaluation room2 cam1 +33.99 +29.32 +5.88 +1.34 -0.0517 -0.0015 +0.0071 -0.0061 fail
Evaluation room3 cam0 +17.92 +17.81 +2.38 -1.88 -0.0291 +0.0052 -0.0027 -0.0024 fail
Evaluation room3 cam1 +14.58 +13.91 +1.40 -6.14 -0.0525 +0.0269 -0.0177 +0.0020 fail
Evaluation room4 cam0 +34.61 +35.19 +3.96 -2.99 -0.0099 -0.0071 +0.0077 -0.0155 fail
Evaluation room4 cam1 +30.65 +32.71 +3.22 -0.63 -0.0167 -0.0063 -0.0028 -0.0077 fail
Evaluation room5 cam0 +15.19 +14.87 +3.12 -4.84 -0.0177 +0.0032 +0.0241 -0.0126 fail
Evaluation room5 cam1 +11.70 +13.38 -2.60 -3.26 -0.0419 +0.0056 +0.0240 -0.0109 fail
Evaluation room6 cam0 +36.49 +36.95 +10.98 -0.53 -0.1020 -0.0152 +0.0337 -0.0091 fail
Evaluation room6 cam1 +45.71 +46.14 +12.20 +8.31 -0.1716 +0.1103 -0.0736 +0.0218 fail

Zero of ten evaluation cases passed. All ten produced finite estimates and failed the focal gate. Focal estimates were +11.70% to +46.14% above Kalibr. Four cases also exceeded the principal-point gate. The full estimates, exact errors, commands, and provenance are in the development JSON and the evaluation JSONs (room2, room3, room4, room5, room6).

Sequence Window (s) Rig displacement (m) Median transfer, cam0 / cam1 (px)
room1 20–30 0.987 2.13 / 2.00
room2 134–144 1.453 3.19 / 3.26
room3 128–138 0.622 2.97 / 2.63
room4 100–110 1.049 4.67 / 3.83
room5 18–28 0.304 1.48 / 1.14
room6 110–120 1.460 3.54 / 3.46

What limited agreement

  • Translation and parallax. The qualifying windows still span 0.304–1.460 m of OptiTrack rig translation. These are the smallest measured displacements among windows that met the rotation requirement. The optical centers also move as the rig turns. The solver fits a rotation-only model, so it can absorb part of the parallax into the intrinsics. Even room5, with the smallest measured displacement, produces focal errors of +11.70% to +15.19%.
  • Tracking and image quality. Every case exceeds the existing 1 px median transfer warning threshold. The highest median is 4.67 px on room4/cam0. These residuals measure disagreement with the fitted model. The audit did not independently measure the contribution from exposure changes, motion blur, or tracking loss.
  • Fisheye periphery. The current inverse model caps rays at 1.45 rad (83.1°) from the optical axis. Evaluating the reference equidistant polynomial at that angle puts about 13% of the full 512 × 512 raster beyond the cap for each camera. This is a raster fraction and includes any pixels outside the usable image circle. The audit did not measure how many tracked features lie in that area or isolate its effect on the fit.

The ROS 1 reader and the bag window option were the only changes to the CLI path. The estimator settings stayed at their normal defaults. A controlled follow-up can turn a global-shutter fisheye around its lens on a tripod, repeat the turn with a measured offset, and compare central and peripheral tracks. That would separate the effects of parallax and the fisheye angle cap.

How it works

  1. Features are tracked with pyramidal Lucas-Kanade, forward-backward checked; a keyframe is taken whenever they moved 15 px (median).
  2. The focal length and k1 are found together on a grid: with them, the undistorted correspondences between keyframes four apart must be related by a rotation. Searching the focal length alone is biased by tens of percent, because barrel distortion bends the image motion the way a shorter lens does (on the simulated camera, 490 px instead of 420).
  3. A least-squares fit refines the eight intrinsics and every keyframe's rotation from the transfer error: a feature seen in one keyframe is undistorted, rotated into another up to four keyframes later and projected with the distortion. The scene points are not unknowns, which keeps the fit small (eight intrinsics and three angles per keyframe) and quick to converge.

A model of the translation (a fixed lens offset from the rotation centre plus each point's depth) was tried on the simulated camera and did not converge to the true offset, so the translation remains a documented limit rather than an estimated quantity.

A gyro does not lift it either. Holding the keyframe rotations to an IMU's (with the camera-IMU rotation and the gyro bias fitted alongside) left the focal length of the camera whose lens is 15 cm off the rotation centre 3.4 % long, as without it: the fitted rotations already matched the gyro's to 0.01 deg. Turning the camera moves the offset lens sideways with the turn, so a scene point at distance Z moves in the image by the rotation's f θ plus the translation's f L θ / Z: f (1 + L/Z) θ. Where the scene's depth varies little that is a longer focal length and the right rotation, which no rotation measurement can tell apart.