Hilti 2022 Camera-IMU Rotation

Calibrex's first targetless camera-IMU calibration. It estimates the rotation of T_cam_imu, the clock offset (t_imu = t_cam + dt), and the gyro bias, by aligning camera rotations from tracked image features with the gyro. No calibration target is needed.

python -m pip install 'calibrex[opencv]'
calibrex camera-imu rotation exp21_ros2 \
  --camchain calibration_files/calib_3_cam0-1-camchain-imucam.yaml --camera cam0 \
  --imu-topic /alphasense/imu \
  --dataset-family hilti2022 --dataset-license "Hilti SLAM Challenge 2022 terms" \
  --output cam0.yaml

The camchain supplies the camera's intrinsics. Its T_cam_imu and timeshift_cam_imu are used only as a comparison. They come from Hilti's target-based Kalibr calibration, which is a reference, not ground truth.

Method

  1. Camera rotations.
  2. Images are contrast-equalized (CLAHE). Up to 600 Shi-Tomasi features (quality 0.001) are tracked with pyramidal Lucas-Kanade across every 4th frame (10 Hz), and undistorted with the camera model.
  3. The frame-to-frame rotation comes from the essential matrix (5-point RANSAC with cheirality). A pure-rotation fit (bearing Kabsch in RANSAC) is the fallback, and it replaces a degenerate essential solution.
  4. The essential matrix is preferred because walking translation produces image flow that a pure rotation absorbs as a rotation of about t / depth. On exp21, a configuration that used pure rotation for about 90 % of the pairs was 0.3-0.5 deg further from Kalibr.
  5. A failed pair ends the track segment; zero motion is never assumed.
  6. Evidence. The same as for MID360 IMU-LiDAR:
  7. every third 10-second window is held out;
  8. an 8-group window jackknife;
  9. 1 deg and 10 ms known-bad controls that held-out windows must detect.
  10. Rotation uncertainty and reference differences are small rotations about the camera axes, so they stay meaningful for cameras mounted near an Euler singularity. The Alphasense cameras are rotated by about 90 deg from the IMU. The reported roll, pitch, and yaw values are xyz Euler angles.

Focal lengths against the gyro (calibrex camera-imu focal)

Tracked camera rotations scale with the focal length that the features were normalized with:

  • a rotation about the camera y axis reads as theta fx_true / fx_used;
  • a rotation about the x axis reads as theta fy_true / fy_used;
  • a rotation about the optical axis does not depend on the focal length.

With the camera-IMU rotation, clock offset, and gyro bias taken from a rotation artifact, calibrex camera-imu focal regresses the camera's angular rates on the gyro's, axis by axis (calibrex.evaluation.camera_focal). The fit is robust and gives fx_est = fx_used k_y and fy_est = fy_used k_x, with no calibration target. Evidence:

  • every third window is held out, and the held-out ratios must agree within 3 std;
  • an 8-group jackknife sets the std;
  • the optical-axis ratio k_z must be 1 within 3 std, otherwise something other than the focal length is scaling the rotations.

A synthetic test tracks with a focal length 3 % too long and recovers the 0.971 ratios on x and y, with 1.000 on z.

exp21 Ratio about x / y / z Std Held-out ratio fx, fy estimate (Kalibr) Verdict
cam0 0.995 / 0.998 / 1.001 0.005 / 0.007 / 0.002 0.993 / 1.005 / 1.009 350.7, 349.8 (351.3, 351.5) px inconclusive (std over 0.005)
cam1 0.994 / 1.002 / 1.004 0.005 / 0.004 / 0.004 0.987 / 0.994 / 0.999 353.4, 350.6 (352.6, 352.9) px pass
cam2 0.977 / 0.988 / 0.999 0.010 / 0.005 / 0.004 1.004 / 0.987 / 1.000 346.4, 342.9 (350.7, 350.9) px inconclusive
cam3 0.977 / 1.013 / 0.997 0.006 / 0.013 / 0.003 1.015 / 0.989 / 1.001 357.5, 345.0 (353.0, 353.3) px fail (held-out disagreement)
cam4 1.012 / 1.003 / 0.995 0.010 / 0.006 / 0.002 0.998 / 1.013 / 0.992 352.5, 356.1 (351.5, 351.8) px inconclusive
  • The forward cameras agree with Kalibr's focal lengths within 0.5 % (about 2 px).
  • The side and down cameras scatter by 1-2 % and fail or miss the bound, in line with their rotation results above.
  • The optical-axis control stays within 0.8 % of 1 on every camera.

Artifacts: docs/assets/hilti2022_camera_imu/focal_cam*_exp21.yaml.

TUM-VI room1 (development) and a pre-registered audit

TUM-VI is a hand-held rig with two 190 deg fisheye cameras (equidistant, 512 x 512) and a BMI160 IMU, calibrated with Kalibr. calibrex check --tf camchain.yaml --pairs camera-imu,camera-focal on room1 (spent), with Kalibr's camchain and with its focal lengths turned 3 % long or short:

Candidate cam0 cam1
Kalibr pass: fx scale 0.9996, fy 1.0113 inconclusive: the estimator failed its own held-out check
focal 3 % long (true scale 0.971) fail: fx 0.977 fail; fy 0.993 within tolerance inconclusive: optical-axis control 0.989
focal 3 % short (true scale 1.031) fail: fx 1.031 fail inconclusive: held-out check
  • fx tracks the injected error.
  • fy does not. It reads about 1 % high at Kalibr's value and does not separate the 3 % errors cleanly.
  • cam1 is often inconclusive.
  • What is claimed. No accuracy claim is made. Check's honesty on the correct focal lengths and its detection of 3 % errors are pre-registered on room2–room6.

Development records.

Result: camera-focal check honesty and detection supported

The pre-registered audit ran once on 2026-11-07, from a worktree at the pre-registration commit (a48efac3), whose src/ and tools/ equal frozen_code_commit (b9eee429). Each case is one sequence, one camera and one candidate; the cell is camera-focal's verdict, with the fx (and fy) scale where judged.

Sequence Kalibr cam0 Kalibr cam1 3 % long cam0 3 % long cam1 3 % short cam0 3 % short cam1
room2 pass (fx 0.9996) inconclusive inconclusive inconclusive warn (1.017, 1.028) inconclusive
room3 pass (1.002, 1.002) inconclusive skipped inconclusive inconclusive inconclusive
room4 pass (fx 1.000) pass (1.002, 1.004) inconclusive inconclusive fail (1.032, 1.039) fail (1.028, 1.034)
room5 pass (1.000, 0.996) inconclusive inconclusive fail (fx 0.975) fail (fx 1.033) fail (1.030, 1.031)
room6 pass (fx 0.995) inconclusive fail (fx 0.982) warn (fx 0.988) inconclusive warn (fx 1.015)

A 3 % long focal length reads as a scale of 0.971; a 3 % short one as 1.031.

  • Honesty: supported.
  • Check never failed Kalibr's focal lengths.
  • It judged a focal length on 6 of 10 cases (gate 25 %).
  • Detection: supported.
  • Check passed none of the 20 cases with a 3 %-wrong focal length.
  • It failed 6 (30 %, gate 25 %) and warned on 3 more.
  • The detection is partial.
  • Half of the perturbed cases came out inconclusive or skipped.
  • In several the estimated scale moved by only half the injected error (1.015–1.017, 0.982–0.988).
  • cam1 is often inconclusive. Its estimator failed its own held-out or optical-axis checks on 4 of 5 sequences even with Kalibr's values.
  • No accuracy is claimed. fx agrees with Kalibr within 0.5 % where judged; fy is noisier.

What this means for a user:

  • On a fisheye camera like TUM-VI's, calibrex check does not flag a correct focal length.
  • It does not pass one that is 3 % off.
  • About half the time it says inconclusive rather than fail.

Run records; audit record. The five sequences are spent.

Rays beyond 90 deg on a fisheye: an incidence cap, tried and not adopted

The tracker turns pixels into perspective rays (tan of the incidence angle). On TUM-VI's 190 deg lenses the image corners lie about 114 deg off the optical axis, and a ray beyond 90 deg flips sign. A cap that drops features beyond a given incidence angle was tried on room1 (spent) only, with the same three candidates:

Cap Kalibr: judged / fails 3 %-wrong: fail / pass (of 4) cam0 fx scale at Kalibr's value
none (current) 1 of 2 / 0 2 / 0 0.9996
80 deg 2 of 2 / 0 (cam0 warn, fy 1.009) 1 / 0 1.0023
65 deg 1 of 2 / 0 3 / 0 1.0024 (inconclusive)
50 deg 1 of 2 / 0 0 / 0 1.0074
  • No cap is better on every count. Detection goes 2, 1, 3, 0 of 4 as the cap tightens.
  • The scale drifts from 1 as the cap tightens. The wide-angle rays are not what makes cam1 inconclusive.
  • fy is judged less often with any cap.
  • Not merged. The default is unchanged. The code is on branch research/fisheye-focal.

Development results

Only exp21 and exp07 were used, for development. exp01-exp04 are held back, untouched, for a pre-registered audit. The artifacts in docs/assets/hilti2022_camera_imu/ come from the current version: CLAHE, and 600 features at quality 0.001.

Camera Recording Difference to Kalibr about camera x / y / z (deg) Analytic std (deg) Jackknife std (deg) Verdict Static windows excluded Controls detected dt (ms)
cam0 exp21 -0.19 / -0.33 / -0.25 0.07 / 0.08 / 0.07 0.12 / 0.12 / 0.15 warn 2 3/4 1.70
cam1 exp21 -0.15 / -0.33 / -0.18 0.06 / 0.07 / 0.06 0.11 / 0.10 / 0.18 pass 2 4/4 1.83
cam2 exp21 -0.28 / -0.24 / +0.15 0.08 / 0.09 / 0.10 0.26 / 0.15 / 0.24 pass 2 4/4 1.59
cam3 exp21 -0.23 / -0.29 / -0.19 0.07 / 0.09 / 0.09 0.23 / 0.13 / 0.31 inconclusive 1 4/4 1.81
cam4 exp21 -0.18 / -0.60 / -0.02 0.09 / 0.12 / 0.11 0.18 / 0.16 / 0.21 pass 1 4/4 1.85
cam0 exp07 -0.23 / -0.20 / -0.20 0.11 / 0.14 / 0.11 0.12 / 0.24 / 0.19 pass 0 4/4 2.06
cam1 exp07 -0.16 / -0.05 / -0.32 0.10 / 0.12 / 0.09 0.10 / 0.18 / 0.18 pass 0 4/4 1.90
cam2 exp07 -0.74 / -1.67 / +0.44 0.13 / 0.14 / 0.20 0.57 / 0.62 / 0.41 inconclusive 0 3/4 1.88
cam3 exp07 -0.40 / -0.79 / +0.38 0.18 / 0.26 / 0.19 0.45 / 0.57 / 0.64 inconclusive 0 4/4 2.65
cam4 exp07 -1.14 / +0.25 / +0.72 0.10 / 0.12 / 0.11 0.35 / 0.60 / 0.70 inconclusive 0 3/4 1.77

Kalibr's dt is 1.91 / 1.90 / 1.94 / 1.81 / 1.71 ms for cam0-cam4. These are the artifacts after the camera-specific evidence settings below; the first version of this table, with the 0.1 deg bound inherited from IMU-LiDAR and no window exclusion, had every verdict inconclusive.

Contrast equalization: what changed. The first version tracked without CLAHE, using 400 features at quality 0.01.

  • Failed frame pairs dropped sharply. On the exp07 corridor, cam0 went from 577 to 16 of 1321, and cam4 from 532 to 137.
  • The forward cameras on exp07 improved. Their differences shrank from up to 0.8 deg to 0.3 deg, and their std from 0.4-0.9 deg to 0.1-0.24 deg.
  • The side-looking cameras did not improve, and two got worse.
  • On exp07, cam2-cam4 are still 0.4-1.7 deg from Kalibr.
  • On exp21, cam3 roll moved from -0.18 to -0.62 deg, and cam4 detects only 2 of 4 controls.
  • Near walls and large parallax are the likely cause, but this is not verified.

The clock offset is within 0.35 ms of Kalibr on every camera except cam3 on exp07 (0.84 ms).

A rig-level offset about the IMU vertical axis

tools/analyze_camera_imu_consistency.py expresses each camera's difference to Kalibr about the IMU axes. It also computes camera-to-camera rotations, in which any common IMU-frame offset cancels.

exp21 First version Current version
Common IMU-frame offset (deg) (-0.14, +0.07, -0.41) (-0.135, -0.055, -0.34)
Per-camera residual after removing it (deg) 0.17-0.40 0.11-0.39 (0.18 / 0.11 / 0.38 / 0.39 / 0.27 for cam0-cam4)

What the evidence shows

  • On exp21 a rotation of about -0.34 deg about the IMU vertical axis is shared by every camera. The cameras face forward (cam0, cam1), down (cam2), left (cam3), and right (cam4).
  • The z component is not reproduced across recordings. The forward cameras' common offset is (-0.22, -0.17, -0.33) deg on exp21 and (-0.26, -0.20, -0.12) deg on exp07: x and y agree, z does not. Only exp21 and exp07 are available, and the side cameras on exp07 are not usable, so the offset about z is not established as a property of the rig.
  • It is not translation leakage. The opposite-facing cam3 and cam4 carry the same sign, whereas leakage would flip it.
  • It is not coning. The rotation increments are already preintegrated.
  • Gyro non-orthogonality is not supported. A full linear fit w_cam = A w_imu on exp21 (cam0 and cam3) gives the same antisymmetric part, about -0.48 deg about IMU z, but inconsistent symmetric parts.

What remains open

The offset lies between the gyro frame, which this method measures, and Kalibr's IMU frame. Kalibr's report lists the IMU model as calibrated: the gyro and the accelerometer are assumed to share one frame. A rotation between them inside the IMU would appear exactly like this, but the data at hand cannot distinguish that from an error in the reference.

Rig and motion parts on exp01 and exp21

The all-camera calibrex check names the IMU on exp21: one turn of its candidate, (+0.32, +0.19, +0.41) deg, explains every camera-imu error (tutorial). tools/hilti_camera_imu_offset.py asks which part of that turn belongs to the rig and which to the motion.

How it works.

  • For each camera, the tool tracks the images as the check does. It then fits the gyro on three sets of moving windows:
  • all of them;
  • the two halves in time, which see different motion;
  • the even and odd windows, which see the same motion, interleaved.
  • It pools the five cameras per split into one rig offset.
  • Convention. w is about the IMU axes, with E = C exp(w). Here C is Kalibr's R_cam_imu and E the estimate. The attribution's turn of the IMU is -w.
  • The z axis is vertical in use. The mean specific force on exp21 is (0.67, −0.01, −9.66) m/s², and the median tilt is 6 deg.
  • Data and windows. The head bags hold 81 s. The fits use 4 s windows, 17 to 19 of them. The check's 10 s windows give 7 to 9 windows: the same picture, with rougher stds.
deg (IMU x / y / z) exp01 exp21
Rig offset, all windows −0.08 ± 0.04 / −0.02 ± 0.05 / −0.39 ± 0.07 −0.23 ± 0.08 / −0.23 ± 0.05 / −0.42 ± 0.04
Cameras' χ² about it (4 dof) 6.9 / 5.7 / 4.3 3.3 / 3.0 / 4.4
First − second half (z-score) −0.22 (−2.7) / +0.28 (+3.2) / −0.33 (−2.1) −0.18 (−1.3) / +0.10 (+0.7) / +0.09 (+0.9)
Even − odd (z-score) +0.03 (+0.4) / −0.03 (−0.4) / +0.03 (+0.2) +0.01 (+0.1) / +0.01 (+0.1) / +0.03 (+0.3)
Rig offset with the check's 10 s windows −0.04 / −0.06 / −0.31 −0.16 / −0.21 / −0.43
z of the rotation part of a full linear fit, per camera −0.01 to −0.55 −0.33 to −0.63

The pooled stds treat the cameras as independent. They share the gyro and the motion, so the stds are optimistic; the χ² shows whether the cameras agree.

What the evidence shows

  • About IMU z, every camera reads the same turn on both recordings: −0.39 and −0.42 deg.
  • The cameras face forward, down, left and right. A camera-side cause would not give one turn about the IMU's axes.
  • This is a rotation between the gyro frame, which camera-imu measures, and Kalibr's IMU frame.
  • exp07's forward cameras read −0.12 deg about z (above), so two of three recordings agree on it.
  • It is not the gyro's scale or non-orthogonality.
  • A full linear fit w_cam = A w_gyro keeps the turn in the rotation part of A.
  • The symmetric parts differ from camera to camera, as found before.
  • The horizontal components move with the motion.
  • They differ between the recordings: −0.23 / −0.23 against −0.08 / −0.02 deg.
  • On exp01 they differ between the halves by up to 0.3 deg (z-scores 2.7 and 3.2). The z component there also moves (−0.58 against −0.25 deg).
  • Interleaved windows agree everywhere. The stds describe the noise within one kind of motion; another part of the recording moves the reading by more. This is the same pattern as the camera pairs.
  • What the check names on exp21 therefore has two parts.
  • The z part, about 0.4 deg, recurs on exp01 with every camera.
  • The x and y part, about 0.2 deg, belongs to exp21's motion.
  • Together they make the 0.5 deg camera-imu errors. At the 0.5 deg floor, they put cam1's pitch at warn (0.51 deg).

What remains open

The data cannot tell whether the gyro frame or Kalibr's IMU frame is off. Kalibr's calibrated IMU model assumes the gyro and accelerometer share one frame. A rotation between them, or a Kalibr error about z, would both look like this.

No verdict rule changes. The motion-dependent part is the open question for camera-imu stds, as for the camera pairs. Results are in docs/assets/hilti2022_camera_imu/offset_{exp01,exp21}_w{4,10}.json.

Why the reported std exceeds 0.1 deg

Every Hilti verdict is inconclusive, and in every case it is the window jackknife that decides it: the analytic std is 0.05-0.11 deg, but the jackknife raises the reported std to 0.08-0.30 deg. tools/diagnose_camera_imu_std.py decomposes the gap on exp21.

For a window, the tracked rotation angle is compared with the gyro angle through the fitted rotation, over that window's intervals. On the two forward cameras the per-window scale (sum(obs*exp)/sum(exp^2)) is not one:

Camera Windows Scale ratio min / median / max Jackknife (x/y/z deg) Analytic (x/y/z deg)
cam0 23 (5 s) 1.001 / 1.020 / 1.081 0.105 / 0.114 / 0.103 0.061 / 0.069 / 0.058
cam0 12 (10 s) 1.006 / 1.022 / 1.072 0.126 / 0.078 / 0.207 0.054 / 0.054 / 0.050
cam0 6 (20 s) 1.012 / 1.025 / 1.038 0.101 / 0.156 / 0.168 0.062 / 0.066 / 0.058
cam1 12 (10 s) - 0.121 / 0.195 / 0.176 0.054 / 0.054 / 0.048
  • The tracked rotation carries a per-window scale of about 1-8 %. The scatter is coherent within a window and differs between windows, so leaving a window out moves the fit by a similar amount: the jackknife turns the scale scatter into the reported std.
  • It is not a focal-length error or a single global scale. A global scale would bias the fit, not scatter the jackknife; a focal error is what calibrex camera-imu focal already checks. The scale here varies with the window's content, consistent with the documented per-pair essential-matrix noise (about 0.07 deg) accumulated differently by each window.
  • Windows with almost no rotation are degenerate. On exp21 the first and last windows turn by under 0.1 deg; they carry no information but still enter the solver, and one of them is often the jackknife group that moves the fit most.

Implication (acted on in the next section). The 0.1 deg bound was inherited from the IMU-LiDAR evaluation, where the motion comes from LiDAR odometry. For image-tracked rotations the window-to-window scale scatter is larger, so that bound marks a well-behaved forward camera unobservable. An audit should either compare the analytic std (which reflects the fit, not the window sampling) or set a bound appropriate to visual tracking, and should not count near-stationary windows in the jackknife.

Camera-specific evidence settings

The diagnosis above led to two changes that apply only to camera-IMU (the IMU-LiDAR defaults and results are unchanged):

  1. Near-static windows are left out of the fit, the jackknife, and the holdout (ImuLidarRunOptions.min_window_rotation_deg, camera default 1.0 deg, IMU-LiDAR default 0 = keep all). A window's rotation is the sum of its per-step angles. On the two forward cameras the windows measured 0.06-0.13 deg (exp21 first and last windows) against 2.5 deg for the smallest moving one, so anything between 0.2 and 2.5 deg separates them; 1.0 deg is ten times the 0.1 deg std asked of the fit. The count is recorded in the artifact (options.static_windows_excluded, with static_windows_excluded_reason and min_window_rotation_deg).
  2. The rotation observability bound is 0.3 deg for cameras (observable_rotation_std_deg, recorded in the artifact options; --observable-rotation-std-deg overrides it). It was chosen from the diagnosis, before re-running: tracked rotations carry a per-window scale scatter of 1-8 % (median 2 %), which the jackknife turns into 0.08-0.30 deg on the forward cameras, so a bound below the top of that range marks a well-behaved camera unobservable. It is 3x the IMU-LiDAR bound, which comes from far more precise LiDAR odometry. No schema changed: both values live in the artifact's free-form options.

What changed on exp21 and exp07

  • Verdicts. 5 of 10 are now pass, 1 warn, 4 inconclusive (before: 10 inconclusive).
  • On exp07 the flips cam0 and cam1 inconclusive to pass come from the threshold alone: no window there is near-static, so the results are otherwise identical.
  • On exp21 one or two windows were excluded per camera (two for cam0-cam2, one for cam3 and cam4). Removing them also shifts the held-out assignment, so exclusion and threshold effects are not separated there.
  • The jackknife is not fixed by exclusion. On exp21 cam0 it went from 0.13 / 0.08 / 0.21 to 0.12 / 0.12 / 0.15 deg: it fell on yaw and rose on pitch. The scale scatter between moving windows remains; the new threshold accommodates it rather than removes it.
  • cam0 exp21 is a warn: a known-bad 1 deg yaw shift is not detected on the held-out windows now that yaw is reported as estimated.
  • Accuracy against Kalibr did not systematically improve. cam0 yaw moved from +0.09 to -0.25 deg; cam4 exp21 passes while its pitch is 0.60 deg from Kalibr (std 0.16), a 3.7 sigma disagreement that the verdict does not see. A pass here means well-constrained and consistent with the held-out windows, not agreement with Kalibr, which is itself only a reference (see the rig-level offset above).
  • The side and down cameras on exp07 still fail to constrain the rotation (jackknife 0.35-0.7 deg, 0.4-1.7 deg from Kalibr); cam3 on exp21 is inconclusive on yaw (0.31 deg). The 0.3 deg bound did not rescue them.

The bound is a judgement made from development data on two recordings. It has been validated on held-out recordings only by the pre-registered audit below, which refuted the claim on the shortest recording (exp04).

Pre-registered audit: refuted

The claim, metrics, and thresholds were committed in hilti_camera_imu_preregistration.yaml (commit c4d51d2, SHA-256 fad67cd1...a3ec1), before camera-imu ran on any evaluation recording. The code was frozen at commit 7fd89ee; src/ and tools/ were identical to it when the audit ran, and the bag hashes matched the pre-registration. The evaluation recordings are exp01-exp04 and the gated cameras are cam0 and cam1 (eight units); development was exp21 and exp07 only. Each unit ran the pre-registered calibrex camera-imu rotation command once (--frame-stride 4 --min-window-rotation-deg 1.0 --observable-rotation-std-deg 0.3), and no run crashed or was repeated. Scoring is tools/score_hilti_camera_imu.py and the audit is built by tools/build_hilti_camera_imu_audit.py, both unchanged (protocol, result, scores, and the eight artifacts beside it).

Verdict: refuted, 6/7 gates. All eight units are usable and scored.

Unit Rotation to Kalibr Time error Constrained Windows Failed pairs Policy
cam0 exp01 0.552 deg -0.33 ms yes 24 0.2 % pass
cam0 exp02 0.435 deg -0.24 ms yes 48 1.6 % pass
cam0 exp03 0.696 deg +0.13 ms yes 36 2.4 % pass
cam0 exp04 0.497 deg -0.02 ms no 14 2.7 % inconclusive
cam1 exp01 0.377 deg -0.08 ms yes 24 0.3 % pass
cam1 exp02 0.383 deg -0.33 ms yes 48 1.4 % pass
cam1 exp03 0.365 deg +0.04 ms yes 35 2.0 % warn
cam1 exp04 0.512 deg -0.33 ms no 15 2.6 % inconclusive

Cross-recording consistency (largest angle between two recordings' estimates): cam0 0.347 deg, cam1 0.430 deg. Relative cam0-to-cam1 rotation error: exp01 0.300, exp02 0.193, exp03 0.375, exp04 0.406 deg.

Requirement Observed Threshold Result
rotation-vs-kalibr (every unit) max 0.696 deg <= 1.0 deg pass
time-offset-vs-kalibr (every unit) max 0.332 ms <= 0.5 ms pass
constrained (every unit) 2 of 8 units not constrained 0 fail
no-failed-units 0 failed 0 pass
cross-recording-consistency max 0.430 deg (cam1) <= 0.75 deg pass
relative-cam0-cam1 max 0.406 deg (exp04) <= 0.5 deg pass
scored-recordings-coverage 4 of 4 recordings >= 3 pass
  • The accuracy and reproducibility gates pass with margin. The worst rotation error against Kalibr is 0.70 deg (development worst 0.45), the worst clock offset error is 0.33 ms, the estimates of one camera agree across recordings to 0.43 deg, and the Kalibr relative rotation is reproduced to 0.41 deg. The rig-level offset seen in development did not break any gate.
  • The constrained gate fails on exp04, for both cameras. exp04 is the shortest recording (125.8 s), and only 14 (cam0) and 15 (cam1) windows survive the static-window exclusion, against 24-48 elsewhere. On cam0 the pitch jackknife std is 0.354 deg (bound 0.3, so pitch is unobservable); on cam1 roll (0.404 deg) and yaw (0.350 deg) are. The three known-bad controls were detected in all of them, and the rotation errors of those units are 0.50 and 0.51 deg, so the data was not wrong; it was not sufficient to constrain every axis to the 0.3 deg the claim required. This is what the observability bound exists to report.
  • cam1 exp03 passes constrained narrowly. Its pitch control was not detected (2 of 3 detected, the minimum) and its policy is warn.
  • Because the claim said "constrained by the data on all three rotation axes", a short recording that cannot do so contradicts it. The pre-registered rule is not changed after seeing this, and the audit stays on the leaderboard.

The result is a mixed one. Against Kalibr, the method is accurate on construction-site recordings, but the claim as written (every unit constrained) does not hold on the shortest recording. The thresholds were set from two development recordings, and the 0.3 deg observability bound did not generalise to the shortest evaluation recording. A future claim could pre-register a minimum recording length or window count, or report constrained per recording rather than per unit, but that would be a new claim on new recordings.

Runtime was 1240 s of wall time with two runs in parallel (cam0 and cam1 each 199, 502, 409, and 129 s for exp01-exp04).

The held-out recordings are now spent for camera-IMU. cam2-cam4 were not run on them.

Pre-registered audit v3: supported (7 of 7 gates)

v3 was committed in hilti_camera_imu_v3_preregistration.yaml (commit adb2981, SHA-256 e32a24e0...eaeece) before camera-IMU ran on any evaluation recording. The code was frozen at ea5ff40; src/ and tools/ were identical to it for every run.

What v3 claims. v1's estimator and command, scored by the method's own per-axis verdicts.

  • Judged axis. The artifact reports the axis estimated (std at most 0.3 deg) and its 1 deg known-bad control is detected on held-out windows. calibrex check applies the same rule before it judges an axis.
  • Gates.
  • Every judged axis is within 1.0 deg of Kalibr.
  • Every judged clock offset is within 0.75 ms.
  • At least half of the axes are judged.
  • A judged axis spans at most 1.0 deg across recordings.
  • The cam0-cam1 rotation is within 0.75 deg per axis judged for both cameras.
  • Thresholds. 1.5 times the worst of the 22 development units (every unit camera-IMU had run on), rounded up to 0.25.

How it ran.

  • Recordings. exp05, exp06, exp11, exp14 and exp18 (74 to 152 s): every Hilti 2022 recording on which no camera-IMU estimate had been made, except exp09 and exp10, which do not fit the disk. The camera-camera audit had read their first 5 GB; it made no camera-IMU estimate.
  • Execution. tools/hilti_camera_sota_evaluate.py camera-imu-v3 downloaded each bag in full, checked its SHA-256 against the pinned one (all five matched), ran cam0 and cam1, and deleted it. All ten runs exited 0 on their only attempt. The whole evaluation took 13 minutes.
  • Records. Every artifact, log and download record is under docs/assets/hilti2022_camera_imu_v3/, with the scores, the six benchmarks, the protocol and the audit.
Requirement Observed Threshold Result
judged-axis-accuracy max 0.528 deg (cam0 exp14 pitch) <= 1.0 deg pass
judged-time-offset max 0.470 ms (cam1 exp05) <= 0.75 ms pass
judged-axis-coverage 26 of 30 axes (87 %) >= 50 % pass
no-failed-units 0 failed 0 pass
judged-axis-consistency max 0.408 deg (cam1 yaw) <= 1.0 deg pass
judged-axis-relative max 0.444 deg (exp14 yaw) <= 0.75 deg pass
scored-recordings-coverage 5 of 5 recordings >= 3 pass

Errors to Kalibr in deg, about the camera's axes. A bold value is an axis the method did not judge; the reason follows it.

Unit Windows Roll Pitch Yaw Clock offset Policy
cam0 exp05 14 -0.007 -0.232 +0.057 -0.10 ms pass
cam0 exp06 16 +0.036 -0.325 +0.102 -0.16 ms pass
cam0 exp11 16 -0.124 -0.389 +0.074 (std 0.445) -0.41 ms inconclusive
cam0 exp14 8 -0.011 -0.528 +0.182 -0.10 ms pass
cam0 exp18 11 -0.057 -0.869 (std 0.338) +0.057 +0.22 ms inconclusive
cam1 exp05 14 -0.076 -0.243 +0.146 -0.47 ms pass
cam1 exp06 18 -0.113 -0.349 -0.060 -0.11 ms pass
cam1 exp11 17 +0.064 -0.458 (control missed) -0.038 -0.41 ms warn
cam1 exp14 8 -0.183 -0.212 -0.262 -0.03 ms pass
cam1 exp18 12 -0.334 -0.682 (std 0.815) -0.168 -0.40 ms inconclusive

What the result says.

  • The axes the method declined to judge include the two largest errors.
  • cam0 exp18 pitch (-0.87 deg) and cam1 exp18 pitch (-0.68 deg) are both reported unobservable.
  • Every judged axis is within 0.53 deg.
  • In development too, the largest error (cam0 exp15 pitch, -0.77 deg) was an axis whose control was missed.
  • The short recordings held. exp14 (74 s) gave exactly 8 windows for each camera, the least a usable unit may have. It judged all six axes, with stds up to 0.28 deg. Its cam0 pitch, -0.53 deg, is the largest judged error.
  • Pitch is negative on every unit, judged or not (-0.21 to -0.87 deg), as in development. For the forward cameras, pitch is about the vertical axis. That fits the rig-level offset about the IMU's vertical axis (above), plus a motion-dependent part.
  • v3 is supported because it claims less than v1 (post-hoc, with v1's unchanged scorer; scores). Under v1's rules these same ten runs are refuted on two gates:
  • constrained fails on three units (cam0 exp11, cam0 exp18, cam1 exp18);
  • the whole relative rotation on exp14 is 0.570 deg, over 0.5 deg.

What the claim does not cover.

  • It covers the two forward cameras of one rig, on one dataset family. The reference is Hilti's Kalibr calibration, not ground truth.
  • It gates only the axes the method judges; 4 of the 30 were not judged.
  • Its clock-offset and relative bounds (0.75 ms, 0.75 deg per axis) are looser than v1's (0.5 ms, 0.5 deg for the whole rotation). They come from the larger development set, by the rule stated before the runs.

TUM-VI: camera-imu check on a second dataset family

The Hilti audits above are accuracy audits of the estimator. On TUM-VI (two 190 deg fisheye cameras and a BMI160 IMU, calibrated with Kalibr) the question is what calibrex check --pairs camera-imu says about a correct and a wrong T_cam_imu.

Development, all on spent sequences:

  • Kalibr's camchain, room1–room6, both cameras (12 cases): all pass. Every case is judged on roll, pitch and yaw. The largest error is 0.39 deg (room6 cam1 roll); the tolerance is 0.5–0.67 deg. These runs came from the camera-focal audit, which runs camera-imu with it.
  • T_cam_imu turned 2 deg about the camera's x, y or z axis, room1 (6 cases): all fail, on the turned axis. The errors read 1.90–2.15 deg.
  • The estimate does not depend on the candidate. A turned candidate's error is the turn plus the estimate's difference from Kalibr: room1 cam0 roll reads 0.01 deg for Kalibr and 2.01 deg turned.

Honesty and detection on the unseen corridor1–corridor5 are pre-registered. Development records.

Result: camera-imu check honesty supported, detection refuted

The pre-registered audit ran once on 2026-11-07, from a worktree at the pre-registration commit (fa426478), whose src/ and tools/ equal frozen_code_commit (db74694a). Each case is one sequence, one camera and one candidate; the cell is camera-imu's verdict, with the turned axis's error in deg (for Kalibr, the largest judged error).

Sequence Camera Kalibr turned about x (roll) about y (pitch) about z (yaw)
corridor1 cam0 pass (max 0.10 yaw) fail (roll 2.06) fail (pitch 2.08) fail (yaw 1.90)
corridor1 cam1 pass (max 0.18 pitch) fail (roll 1.90) fail (pitch 2.18) fail (yaw 2.02)
corridor2 cam0 pass (max 0.29 roll) fail (roll 1.71) fail (pitch 1.86) fail (yaw 2.04)
corridor2 cam1 pass (max 0.27 roll), pitch unchecked fail (roll 1.73) pass (pitch unchecked) fail (yaw 2.11)
corridor3 cam0 pass (max 0.31 roll) fail (roll 1.69) fail (pitch 2.17) fail (yaw 2.00)
corridor3 cam1 pass (max 0.37 roll) fail (roll 1.63) fail (pitch 2.14) fail (yaw 1.99)
corridor4 cam0 pass (max 0.42 roll), pitch unchecked fail (roll 1.58) pass (pitch unchecked) fail (yaw 1.89)
corridor4 cam1 pass (max 0.44 roll), pitch unchecked fail (roll 1.56) pass (pitch unchecked) fail (yaw 1.95)
corridor5 cam0 pass (max 0.30 roll) fail (roll 1.70) fail (pitch 1.81) fail (yaw 1.94)
corridor5 cam1 pass (max 0.30 roll), pitch unchecked fail (roll 1.70) pass (pitch unchecked) fail (yaw 1.92)
  • Honesty: supported.
  • Check never failed Kalibr's T_cam_imu.
  • It judged rotation axes on 10 of 10 cases (gate 50 %), all three axes on 6.
  • Detection: refuted.
  • Check passed 4 of the 30 turned cases (gate: none). All four are the pitch turn on a case where pitch was not judged:
    • corridor2 cam1 and corridor4 cam0: the estimator's 1 deg known-bad control on pitch was not detected on held-out windows;
    • corridor4 cam1 and corridor5 cam1: pitch was not constrained by the data.
  • Check printed pass (partial: roll, yaw only) and a partial-coverage warning on each.
  • The other 26 (87 %, gate 50 %) failed on the turned axis. Every turned axis that was judged failed (26 of 26), at 1.56–2.18 deg.
  • The estimate reads roll 0.27–0.44 deg below Kalibr's on every corridor case on both cameras. This is within the 0.5 deg tolerance, and room6 read the same (0.33, 0.39). No accuracy is claimed.

What this means for a user:

  • calibrex check did not flag a correct camera-IMU rotation on these fisheye recordings.
  • A 2 deg error on an axis it judges is flagged on that axis.
  • A pass with unchecked axes vouches only for the judged axes. Check says so in the verdict (partial) and in a warning, but with --fail-on fail (the default) it still exits 0. A 2 deg error on an unchecked axis passes.

Run records; audit record. The five sequences are spent.

v2: the same check with --fail-on partial, pre-registered

calibrex check --fail-on partial exits 1 on a pass that left axes unchecked. v2 asks what a user running with it gets. A case is flagged when its camera-imu pair would make the run exit 1.

On the spent rooms and corridors, scored this way:

  • Kalibr's camchain was never failed. It passed with full coverage on 18 of 22 cases; the other 4 left pitch unchecked and would exit 1.
  • No turned case would exit 0. 32 of 36 failed on the turned axis.

Honesty (no fail; full passes on at least 50 %) and detection (no turned case unflagged; at least 50 % failed on the turned axis) are pre-registered on the five smallest unseen sequences: slides1–slides3, magistrale3 and magistrale5. v1 stays refuted.

Result v2: supported, --fail-on partial flags every turned case

The pre-registered audit ran once on 2026-11-07, from a worktree at the pre-registration commit (7899e471), whose src/ and tools/ equal frozen_code_commit (317339c1). The four candidates of a sequence shared one estimator cache. The cell is camera-imu's verdict, with the turned axis's error in deg (for Kalibr, the largest judged error). partial marks a pass that left an axis unchecked; it exits 1 under --fail-on partial.

Sequence Camera Kalibr turned about x (roll) about y (pitch) about z (yaw)
slides2 cam0 pass, partial: pitch unchecked (max 0.22 yaw) fail (roll 1.92) pass, partial: pitch unchecked fail (yaw 1.78)
slides2 cam1 pass, partial: pitch unchecked (max 0.17 roll) fail (roll 1.83) pass, partial: pitch unchecked fail (yaw 1.85)
slides1 cam0 pass (max 0.17 roll) fail (roll 2.17) fail (pitch 2.01) fail (yaw 1.90)
slides1 cam1 pass (max 0.27 pitch) fail (roll 1.90) fail (pitch 2.27) fail (yaw 1.94)
slides3 cam0 pass (max 0.08 roll) fail (roll 1.92) fail (pitch 1.99) fail (yaw 2.01)
slides3 cam1 pass (max 0.19 roll) fail (roll 1.81) fail (pitch 2.06) fail (yaw 1.88)
magistrale5 cam0 pass (max 0.20 pitch) fail (roll 2.02) fail (pitch 1.80) fail (yaw 1.93)
magistrale5 cam1 pass (max 0.17 pitch) fail (roll 1.96) fail (pitch 2.17) fail (yaw 1.90)
magistrale3 cam0 pass (max 0.20 pitch) fail (roll 1.94) fail (pitch 1.80) fail (yaw 1.84)
magistrale3 cam1 pass (max 0.12 roll) fail (roll 1.88) fail (pitch 2.10) fail (yaw 2.01)
  • Honesty: supported.
  • Check never failed Kalibr's T_cam_imu.
  • It passed with full coverage on 8 of 10 cases (gate 50 %).
  • Both slides2 cameras left pitch unchecked; under --fail-on partial those two runs exit 1 although the calibration is right.
  • Detection: supported.
  • Under --fail-on partial no turned case exits 0 (gate: none). The slides2 pitch turns passed with pitch unchecked, as in v1, and are now flagged.
  • 28 of 30 failed on the turned axis (gate 50 %), at 1.78–2.27 deg.
  • The same pattern as v1. Every judged turned axis failed; the misses are an axis the recording could not judge.

What this means for a user:

  • With --fail-on partial, a 2 deg camera-IMU rotation error did not get through on these recordings.
  • The price is a non-zero exit on a correct calibration when the recording cannot judge an axis (2 of 10 here). Re-record with more rotation about that axis.

Run records; audit record. The five sequences are spent.

Next steps

  • Understand the side-camera errors.
  • Decide how the audit treats a rig-level IMU-frame offset. The rotation of each camera relative to the gyro frame is what this method estimates.
  • Decide how observability is judged. The pre-registered audit on exp01-exp04 was refuted by the constrained gate on the 126 s exp04 alone. Its successor, v2, kept every gate and required recordings of at least 200 s; it was refuted too (v2 audit).
  • Yaw was not constrained on two units of 260 s and 321 s (cam0 exp15, cam1 exp23p1), so length is not what decides it.
  • cam0's estimates spread 0.81 deg across the five recordings, over the 0.75 deg consistency bound.
  • A new claim needs new recordings (exp01-exp04 and the five v2 recordings are spent) and, ideally, a targetless external baseline.
  • v3 is supported (above). It gates only the axes the method judges, and requires at least half of them judged.
  • A stronger claim, every axis constrained as v1 asked, would need recordings with more excitation about the camera's pitch axis.
  • Hilti 2022 has only exp09 and exp10 left for camera-IMU, too large for this environment.

camera-IMU has one supported claim, v3, within the scope stated in it. v1 and v2 stay refuted and listed.