Stereo surface registration with existing tangent-plane ICP

Frozen experiment

Use the existing Chen–Medioni discrete tangent-plane ICP implementation rather than extending the image-support penalty. Correspondences are refreshed 3D nearest neighbors with mutual checks, a 0.5 m gate and 80% point-plane trimming. Target normals come from local PCA; rank/condition checks and a spatial 20% source holdout are retained. Multi-start and effective-curvature diagnostics are disabled for bounded runtime. The holdout is a spatial subset of the same frame, not independent sensor truth or a separate recording.

Before real-data execution, five controlled three-plane tests recover <0.05 deg and <5 mm pose error and <5 mm holdout plane RMSE: complete surfaces, target holes, partial source overlap with distant unmatched points, their combination, and a foreground patch replacing a background patch only in the target. These are geometric point-cloud controls, not a realistic stereo noise/synchronization simulation. They validate recovery with missing/conflicting geometry, beyond continuity alone.

Freeze code/options/protocol before real execution. Use the middle archived frame for each of six spent recordings and both original initial perturbations: 12 ICP fits and 12 newly matched single-frame D2D controls. Both receive the same raw frame depth, cloud, intrinsics and initial pose. Do not compare success rates as though the historical three-frame D2D run used the same observations.

Backproject valid 0.1–80 m stereo depth into original-left camera coordinates. Select LiDAR points in the initial camera field of view and depth range, without using reference calibration. For ICP only, deterministically retain the first point in 0.2 m voxels then uniformly cap at 6,000 points per cloud. D2D retains its existing preprocessing/defaults. No target-normal filling, support-field penalty or cross-frame point association is introduced.

ICP retains its 50-iteration default and 1e-7 update tolerance. Report all raw candidates, status, source/target sizes, train/holdout plane residuals, tangent rank/condition and signed probes. Treat converged as numerical acceptance only; score the unchanged <0.5 deg and <0.20 m gates after both fits. Non-converged ICP returns the original pose while preserving the raw candidate when available. Represent nonfinite diagnostic evidence explicitly as strings, not JSON NaN.

No defaults are promoted, no fresh evaluation inputs read, and no accuracy-driven reruns or parameter changes are allowed. Compare all twelve cases, including failed geometry or support, without counting a rejected candidate as recovery.

PYTHONPATH=src:. OPENBLAS_NUM_THREADS=1 \
  python tools/evaluate_stereo_surface_registration.py \
  docs/assets/stereo_surface_registration_20261029/plan.json /tmp/surface-icp.json

Results

Code, settings and protocol were frozen at 464279c5. Five controlled geometry scenarios and the five existing tangent-ICP tests passed. All 24 real fits (12 ICP plus 12 newly matched D2D controls) completed without outcome-based retries or changes to thresholds.

  • Surface ICP recovery: 0/12. Seven converge, but all seven fail joint reference-accuracy gates. Five hit the iteration limit and return the exact initializer, with raw candidates retained.
  • Matched single-frame D2D recovery: 3/12. This is not the historical three-frame D2D result of 5/12; do not replace or reinterpret that verdict.
  • All ICP fits have tangent rank six. Spatial holdout point-plane RMSE spans 0.0317–0.0712 m, yet none meets full-pose accuracy criteria. Local rank and same-frame held-out residuals are not sufficient accuracy evidence.

Raw translation differences below are metres to the dataset reference; rotations are degrees. Rejected ICP candidates are shown for diagnosis only.

Recording / seed ICP status ICP raw rotation ICP raw translation Holdout plane RMSE D2D rotation D2D translation D2D recovered
0005 positive max_iterations 1.2815 0.3921 0.0626 1.1977 0.3189 False
0005 negative max_iterations 0.1973 0.4431 0.0651 0.5732 0.1946 False
0002 positive converged 0.7461 0.3220 0.0317 0.3910 0.2365 False
0002 negative converged 0.9472 0.3287 0.0360 0.0214 0.1658 True
0009 positive max_iterations 0.9588 0.2269 0.0524 1.1283 0.1820 False
0009 negative max_iterations 0.5832 0.1624 0.0538 0.2968 0.2473 False
0011 positive converged 1.1247 0.2782 0.0357 0.3341 0.1641 True
0011 negative max_iterations 1.8009 0.7149 0.0359 0.3382 0.5852 False
0013 positive converged 0.6415 0.1514 0.0414 0.9923 0.3163 False
0013 negative converged 0.7947 0.1753 0.0428 1.1291 0.4390 False
0015 positive converged 0.3267 0.2740 0.0531 0.3668 0.1958 True
0015 negative converged 1.4670 0.5643 0.0712 0.4221 0.2184 False

What this changes

The controlled tests now exercise actual pose recovery with missing, conflicting and partially overlapping surfaces, not just objective continuity. However, those idealized clouds do not reproduce noisy stereo reconstruction, correlated surface bias, time alignment or realistic cross-sensor occlusion. Their success does not predict real calibration success.

The real test replaces projective matching with existing mutual 3D matching and robust tangent-plane trimming, yet fails to produce a qualifying pose. That is evidence against adopting this specific adapter/settings, not against ICP in all settings or against the original Chen–Medioni method. It also shows why a spatial holdout drawn from the same potentially biased stereo target is not an independent check of camera/LiDAR calibration.

Decision

Keep the adapter experimental; no solver or frontend defaults change. Do not relax convergence, fit acceptance thresholds to these twelve outcomes, or report the seven converged poses as successful calibrations. Preserve all 24 outputs.

The next substantive comparison should challenge the shared stereo reconstruction assumption with an independently specified depth/correspondence source, rather than another nearest-neighbor or penalty variant over the same depth arrays. Any new source must have reproducible version/settings, clear input/calibration requirements and the same complete failure-aware comparison. No fresh evaluation or SOTA claim follows from these development experiments.

Evaluation, schema, execution log, test log and frozen settings preserve reference/input identities, source/target counts, normal/rank statistics, correspondence histories, holdout evidence and signed perturbation probes. Nonfinite evidence, if present, is represented explicitly by strings.