Why radar-imu judges yaw and not roll or pitch (spent data, 2026-11-11)¶
The radar-imu audits judged only yaw, the rotation about each radar's z axis
(radar-imu). The unjudged roll came out up to 2.9 deg
(4 std) off the authors' rotation. This note looks for the cause, on spent data only:
- ICINS 2021 (9 bags);
- JGN 2022 (4 bags × 3 radars).
The pseudo ground truth of ICINS is used for diagnosis only, never by the estimator. No method change came out of it.
The radar's own z velocity is the limit¶
Each scan's Doppler ego velocity was compared with the radar velocity predicted from the pseudo ground truth trajectory (VINS with loop closure, about 4 Hz, spline-differentiated) and the authors' extrinsic. carried_1, carried_2 and carried_4 give:
| Radar axis | error std (m/s) | measured / predicted slope |
|---|---|---|
| x | 0.040–0.042 | 0.98–1.00 |
| y | 0.036–0.040 | 0.99–1.02 |
| z | 0.089–0.106 | 1.03–1.06 |
- The z component is 2.5 times noisier and reads 3–6 % large.
- The z velocity also varies little in these recordings: its std is 0.10–0.13 m/s, about the size of its noise (S/N 1.1–1.2), against 0.17–0.24 m/s on x and y.
- A turn about the radar's x or y axis moves the velocity into z. Roll and pitch are therefore read almost only through the noisiest, least-excited component.
- Yaw only mixes x and y, which is why it is judged.
Three remedies tried, none kept¶
| Remedy | Result |
|---|---|
| A fitted scale on the radar's z velocity, as a nuisance | rejected: it came out 0.16–0.73 (against about 1.05 from the ground truth); the noise drags it toward zero (errors-in-variables attenuation), and roll and pitch got worse, with larger stds |
| Filtering the returns by SNR (3 or 6 dB) or by angle (elevation 45 deg, azimuth 60 deg, as x_rio does) | no effect from SNR (every return passes); the angle filter made every component noisier |
| Weighted least squares with a per-radar-axis noise model, estimated from the fit's own residuals (two passes) | no consistent change; the noise model is sound (z 2–4 times x and y), but the roll and pitch errors moved both ways |
The errors are systematic per recording¶
The remaining roll and pitch errors are not noise that more weighting would average away: - Across recordings: the same radar's roll changes by 1–3 deg from one recording to the next. For example, JGN's right radar gives +0.9, -2.7, -2.5 and -1.1 deg. - Within a recording: the fold spread is 0.1–0.5 deg.
Something that changes with the recording and is not in the model sets them. Candidates: - the motion-dependent effect of the z scale; - multipath; - the IMU's g-sensitivity.
These data cannot tell them apart.
What follows¶
- The method stays as it is. Its gating already declines to judge roll and pitch: their std or their held-out control keeps them out. That is the honest answer for this radar.
- Judging roll and pitch needs better z data. Either a radar with better elevation (for example a cascaded imaging radar), or motion that moves the rig up and down and tilts it while it travels.
- Recordings like that are a candidate for a new pre-registered audit. One with per-recording ground truth would also tell the systematic error's cause apart.
An imaging radar: Snail-Radar (Oculii Eagle G7)¶
Tested on 2026-11-12, on development data only. Snail-Radar (Huai et al., IJRR; Open Database License) records an Oculii Eagle G7 4D imaging radar and a Bynav X36D IMU (100 Hz) on three platforms. Three sequences were spent as development data, chosen before any of them was read:
| Sequence | Platform | Length | Roll std / error | Pitch std / error | Yaw std / error | Judged |
|---|---|---|---|---|---|---|
| 20230921/data4 | hand-held | 622 s | 0.63 / -2.0 deg | 0.53 / +0.4 deg | 1.26 / -3.0 deg | none |
| 20231019/data2 | e-bike | 533 s | 1.35 / -1.3 deg | 1.11 / -0.2 deg | 0.86 / +0.1 deg | none |
| 20240113/data5 | SUV | 1509 s | 0.32 / -1.4 deg | 0.28 / +1.4 deg | 0.37 / -1.3 deg | none (stds pass, held-out 1 deg controls not detected) |
The errors are to the authors' Oculii-to-X36D rotation. The authors fitted that rotation on 20240113/data5 from the radar's ego velocity and the X36D's INS solution. The estimator is the package's, unchanged.
- The imaging radar's z velocity is no better.
- Measured against the IMU's 1 s velocity changes, the radar's vertical part is uncorrelated (r = -0.04 to 0.09).
- Its RMS difference is 0.26-0.57 m/s, against a vertical excitation of 0.04-0.14 m/s (S/N 0.1-0.5, against about 1.1 for the TI radars).
- Against the INS velocity on the SUV, the radar's z follows with a slope of 0.05, a residual of 0.27 m/s and a bias of -0.15 m/s.
- Horizontally the radar is good: r = 0.85-0.96 against the IMU on the e-bike and the SUV.
- Why: the Eagle's Doppler is quantised in steps of 0.136 m/s, and the returns span only about 4.5 deg of elevation in a scan. Its formal z std (0.036 m/s per scan) is far from the observed scatter.
- A z bias proportional to speed looks like a pitch turn. The two cannot be told apart from velocities alone. On the SUV the package's fit and a direct alignment to the INS velocity agree on pitch (+1.3 and +1.1 deg from the authors' rotation) but not on roll (-1.5 and -2.6 deg) or yaw (-1.2 and -0.1 deg). The clock offset ran to the search bound (-100 ms; -157 ms with a 0.5 s bound, std 33 ms), although the dataset is synchronised to about 10 ms.
- The check stays honest here. No axis would be judged on any of the three, so the authors' rotation would not be failed. It also checks nothing.
Conclusion: an imaging radar with this elevation behaviour does not make roll and pitch judgeable. No pre-registered evaluation was run on the unseen Snail-Radar sequences: with no development sequence judging roll or pitch, its gates would be zero. The other 41 sequences stay unseen.
What was read:
- the three sequences' Eagle point clouds (eagleg7/pcl), X36D IMU and tf_static.launch,
taken out of the per-sequence zips over HTTP range requests;
- their rows of the INS reference (utm50r_T_x36dimu.txt), used for diagnosis only.
The reference archive (ref_trajs.zip) and the time-correction tables were downloaded
whole, but only these three sequences' entries were opened.
One bug was found on the way. The X36D repeats about 1 in 500 IMU stamps, and that stopped the estimator (attitude interpolation needs increasing times). A repeated stamp is now kept once.